Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
HOME | ABOUT US | EDITORIAL BOARD | AHEAD OF PRINT | CURRENT ISSUE | ARCHIVES | INSTRUCTIONS | SUBSCRIBE | ADVERTISE | CONTACT
Indian Journal of Dental Research   Login   |  Users online:

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         

 


 
ORIGINAL RESEARCH Table of Contents   
Year : 2011  |  Volume : 22  |  Issue : 1  |  Page : 95-99
Frictional characteristics of the newer orthodontic elastomeric ligatures


Department of Orthodontics and Dentofacial Orthopedics, PMNM Dental College and Hospital, Bagalkot, Karnataka, India

Correspondence Address:
Anna Cecilia Vaz
Department of Orthodontics and Dentofacial Orthopedics, PMNM Dental College and Hospital, Bagalkot, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.80005

Rights and Permissions

Introduction: Elastomeric ligatures reduce chairside time but increase friction. Polymeric coatings and 45° angulations have been introduced to the ligature modules to combat its disadvantages and reduce friction. This in vitro study compared the frictional characteristics of six different types of the most commonly used elastomeric modules. Materials and Methods: Thecoefficient of friction for six ligation methods: the non-coated Mini Stix and coated Super Slick Mini Stix™ (TP Orthodontics), 45° angulated but non-coated Alastik Easy-To-Tie™ (3M Unitek) elastomerics and non-angulated non-coated Alastik QuiK-StiK * , 0.110'- and 0.120'-diameter elastomerics™ (Reliance Orthodontics) were measured in dry conditions utilizing a jig according to the protocol of Tidy. Results: A significant difference was observed between the various types of elastomeric ligatures (P<.01). Among the six types of elastomeric ligatures, the 45° angulated elastomeric ligatures produced the least friction, followed by the coated Super Slick elastomers. No difference in the friction was noted when the diameter of the elastomeric ligatures was varied. Conclusions: Polymeric surface coatings and introduction of angulations into elastomeric ligatures reduce the friction during sliding; however, the diameter of the ligature made no difference to sliding friction.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed9870    
    Printed489    
    Emailed4    
    PDF Downloaded285    
    Comments [Add]    
    Cited by others 5    

Recommend this journal