Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
HOME | ABOUT US | EDITORIAL BOARD | AHEAD OF PRINT | CURRENT ISSUE | ARCHIVES | INSTRUCTIONS | SUBSCRIBE | ADVERTISE | CONTACT
Indian Journal of Dental Research   Login   |  Users online:

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         

 


 
Table of Contents   
ORIGINAL RESEARCH  
Year : 2012  |  Volume : 23  |  Issue : 1  |  Page : 75-79
The effect of urea on the corrosion behavior of different dental alloys


1 Department of Prosthodontics, Istanbul University, Faculty of Dentistry, 2nd Floor, Capa - 34390, Istanbul, Turkey
2 Professor Emeritus at the Baltimore College of Dental Surgery Dental School, University of Maryland, 666 W. Baltimore St., Baltimore, MD - 21201, USA

Click here for correspondence address and email

Date of Submission31-May-2010
Date of Decision08-Sep-2010
Date of Acceptance27-Jun-2010
Date of Web Publication26-Jul-2012
 

   Abstract 

Objective: Intraoral corrosion of dental alloys has biological, functional, and esthetic consequences. Since it is well known that the salivary urea concentrations undergo changes with various diseases, the present study was undertaken to determine the effect of salivary urea concentrations on the corrosion behavior of commonly used dental casting alloys.
Materials and Methods: Three casting alloys were subjected to polarization scans in synthetic saliva with three different urea concentrations.
Results: Cyclic polarization clearly showed that urea levels above 20 mg/100 ml decreased corrosion current densities, increased the corrosion potentials and, at much higher urea levels, the breakdown potentials.
Conclusion: The data indicate that elevated urea levels reduced the corrosion susceptibility of all alloys, possibly through adsorption of organics onto the metal surface. This study indicates that corrosion testing performed in sterile saline or synthetic saliva without organic components could be misleading.

Keywords: Corrosion, dental/craniofacial material, protein adsorption

How to cite this article:
Geckili O, Bilhan H, Bilgin T, Anthony von Fraunhofer J. The effect of urea on the corrosion behavior of different dental alloys. Indian J Dent Res 2012;23:75-9

How to cite this URL:
Geckili O, Bilhan H, Bilgin T, Anthony von Fraunhofer J. The effect of urea on the corrosion behavior of different dental alloys. Indian J Dent Res [serial online] 2012 [cited 2023 Oct 3];23:75-9. Available from: https://www.ijdr.in/text.asp?2012/23/1/75/99043
A variety of metals and alloys are used in dentistry for the fabrication of restorations. Since the intraoral environment is a near-perfect medium for stimulating corrosion, all alloys used in dentistry are required to possess corrosion resistance. Human saliva is composed of a mixture of organic and inorganic ingredients. [1] Metallic resistance to corrosion in the oral cavity, thus its biocompatibility, plays an important role in the choice of a restorative material. [1],[2] Insufficient corrosion resistance leads to discoloration and deterioration of mechanical properties while the corrosion products can harm the biological system of the host. [3]

Corrosion of dental alloys has biological, functional as well as esthetic effects and the use of nonprecious alloys in crown and bridge restorations is a much discussed subject, notably because the release of metallic components and ions from a prosthetic restoration could be harmful to the health status of a patient. The most important alloys in this respect are nickel-containing alloys which are still used widely in dental restorations but are suspected to cause allergic reactions. [4],[5],[6]

Potentiodynamic polarization methods have been used extensively to study the corrosion of dental implant materials in synthetic saliva. [7] Multiple studies have shown that CrNi dental alloys will corrode in saliva, 0.9% saline solution, and synthetic saliva. [8],[9],[10],[11],[12],[13] Other studies, however, suggest that CrCo and CrNi alloys exhibit good corrosion resistance under the potential and electrolyte conditions appropriate to synthetic saliva. [14]

Organic molecules present in saliva such as glycoproteins can be important in corrosion and studies indicate that corrosion inhibition involves the adsorption of organics onto the metal surface. [9],[15],[16],[17] Salivary levels of urea are higher in patients with diabetes mellitus and in patients undergoing hemodialysis treatment. [18],[19],[20],[21],[22] It has been previously reported that patients with many concomitant diseases exhibited both reduced salivary flow and higher concentrations of biochemical constituents in their saliva. [20] Johansson [23] found that children with dental erosion had higher salivary urea concentrations, while thalassemic patients showed lower salivary urea concentrations. [24]

In view of this, it was decided to evaluate the effect of salivary urea levels on the corrosion behavior of three different casting alloys that are most often used for the fabrication of removable partial denture (RPD) frameworks and for crown-and-bridge castings. The aim of this study was to compare the electrochemical behavior of these dental alloys in synthetic saliva containing different concentrations of urea.


   Materials and Methods Top


The dental alloys studied here were as follows:

  • Co-Cr-Mo alloy (DEGUSSA, Degussa-Hüls AG/Germany; 63% Co, 28%Cr, 5% Mo, and 4% minor components).
  • Ni-Cr-Mo alloy (Suissor FDX 1500/S2® ; METALOR, Metaux Précieux SA, Metalor/Switzerland; 63.3% Ni, 23.5% Cr, 8.75% Mo, 1.6% Si, <1% Y, and <1% Fe).
  • Au-Pt alloy (Degudent U, Degudent GmbH, DENTSPLY Canada Ltd.; 77.3%.
  • Au, 9.8% Pt, 8.9% Pd, 0.1% Ir, 1.2% Ag, 0.3% Cu, 0.5% Sn, 1.5% In, 0.2% Re, and 0.2% Fe).


Synthetic saliva was prepared using the formula suggested by Shannon, [25] [Table 1], with the solution pH adjusted to 6.5-7 by using a platinum electrode (Cole-Parmer Instrument Company, Vernon Hills, IL, USA). No fluoride was present in the solution to avoid conflicting effects of this corrosive anion.
Table 1: The composition of synthetic saliva solution[25]

Click here to view


The urea levels used in this study were based on the findings of Jenkins, [2] namely 200 mg/l (i.e., average value), 120 mg/l (minimum value) and 700 mg/l (maximum value). The test solutions were prepared using commercially available urea (Sigma® chemical company) and weighing was performed on a Mettler AE 100® precision balance. The control solution was synthetic saliva without urea. All test media were maintained at 37±1°C (Mariner Heater and Thermostat, Springfield Electrical Co. Ltd., Thruxton Industrial Estate-Nr-Andover; Hampshire SP 11 8PW). Corrosion tests were performed with an EG & G, PAR Model 273 potentiostat and M352 Corrosion Analysis software at scanning rate of 0.5 mV/sec. A standard three-electrode cell consisting of the alloy sample as the working electrode, a saturated calomel reference electrode (SCE) and a graphite counter electrode was used for the polarization studies. Each metal test specimen was cast as a cylinder (6 mm in height and 16 mm in diameter) and was seated in a Teflon holder with an exposed surface area of 7.5 mm2, all other surfaces being coated with sticky wax to prevent crevice corrosion.

Before corrosion testing, all specimens were wet ground successively with 220, 500, 600, 800, and 1200 grit silicon carbide abrasive papers. After polishing, each specimen was ultrasonically cleaned in distilled water followed by ethanol rinsing prior to testing.

Each alloy was tested in the three test media. The control solution, the potentiostat and associated software plotted the polarization curves. General anodic electrochemical behavior, corrosion current densities (μA/cm 2 ), corrosion potentials (mV), anodic and cathodic Tafel slopes (mV/decade), and pitting potentials (mV), were recorded and the latter was evaluated by cyclic polarization. All polarization studies were performed in triplicate.


   Results Top


The cyclic polarization curves of CrCo, CrNi, and AuPt in synthetic saliva with the three different urea concentrations are shown in [Figure 1], [Figure 2] and [Figure 3]. The mean values (and their standard deviations) of the test parameters [corrosion potential (E corr ), corrosion current density (I corr ) and breakdown potentials] for the three test alloys in the plain synthetic saliva solution and with different urea concentrations at 37°C are presented in [Table 2].
Figure 1: Polarization curves of CrCo alloy in different urea concentrations (12 mg-20 mg-70 mg)

Click here to view
Figure 2: Polarization curves of CrNi alloy in different urea concentrations (12 mg-20 mg-70 mg)

Click here to view
Figure 3: Polarization curves of AuPt alloy in different urea concentrations (12 mg-20 mg-70 mg)

Click here to view
Table 2: Mean values and standard deviations of Ecorr, Icorr and brakdown potentials (EB) for CrCo, CrNi and AuPt alloys in synthetic saliva containing different urea

Click here to view


The polarization behavior of CrCo indicated that the corrosion potential (E corr ) shifted in the anodic direction with increase in the solution urea level [Figure 1] and [Table 2]. These shifts were statistically significant (P<0.001). There was a dramatic increase in I corr for the 120 mg/l and 200 mg/l solutions (P>0.001) compared to the control but there was a marked drop I corr for the 700 mg/l urea solution (P>0.001) [Table 2]. The breakdown potentials shifted anodically for the CoCr alloy in all media compared to the control (P<0.001) although it was found that there was no difference (P>0.05) in the breakdown potentials (E B ) for the 200 mg/l and 700 mg/l solutions.

The cyclic polarization curves for CrNi alloy showed little difference in behavior for synthetic saliva alone and with different urea levels [Figure 2]. Further, the hysteresis loop of cyclic polarization curves for the CrNi alloy was far narrower than that observed with the CrCo alloy. While there was an anodic shift in the corrosion potential E corr (P<0.001) for this alloy in synthetic saliva with increasing urea concentration, the potential shift (ca. 180 mV) was less than that for CrCo (ca. 330 mV) in the 700 mg/l solution. There was no difference (P<0.05) in E corr in the 120 and 200 mg/l solutions. It was found that I corr increased markedly in the 120 mg/L and 200 mg/L solutions compared to the control but there was a marked drop I corr for the 700 mg/l urea solution [Table 2]. Similar to the CrCo alloy, the CrNi alloy showed a marked shift in the breakdown potential with increasing urea concentration but the shift was larger (450 mV) for CrNi than that for CrCo (150 mV).

The cyclic polarization curves for the AuPt alloy showed few apparent differences between the behavior in the control and test solutions and no significant hysteresis loop was evident in any of the polarization curves [Figure 3]. Small but statistically significant (P<0.01 or P<0.001) anodic shifts in E corr were noted in the 200 and 700 mg/l solutions but there was no difference (P>0.05) in E corr for plain synthetic saliva and saliva containing 120 mg/l. Variation was noted in I corr values in the four test media with significant differences (P<0.001) in the 200 and 700 mg/l solutions but not the 120 mg/l solution (P>0.05). The breakdown potential (E B ) of the AuPt alloy shifted anodically in the 200 and 700 mg/l solution, (P<0.001) but not in the 120 mg/l solution (P>0.05).


   Discussion Top


A prosthetic restoration releasing metallic ions due to corrosion can be harmful to the health status of a patient and the greatest concern is directed at nickel-containing alloys because of their association with allergic reactions. [4],[5],[6] Any factor that might enhance such metal ion release clearly has clinical significance. The present study is part of an ongoing program of work evaluating the effect of organic salivary components on the corrosion of dental metals in artificial saliva.

Traditionally, noble metals were the alloys of choice for the fabrication of prostheses but as precious metal costs rose, the trend has been toward the greater use of base metal alloys, notably chromium-containing alloys, for prostheses. Chromium is added to nickel alloys in order to enhance corrosion resistance through surface oxide film formation. Additions of 16-27% chromium are reported to provide optimal corrosion resistance, while small additions of molybdenum enhance corrosion resistance, specifically to pitting. [10] Nickel alloys with lower chromium contents do not form a sufficiently protective oxide layer. Similar considerations apply to cobalt-base alloys. Several studies have shown variation in salivary urea levels with different diseases. [18],[19],[20],[21],[22],[23] Since glycoproteins have been shown to be important with regard to corrosion, it is to be expected that changes in salivary urea levels will affect the corrosion behavior of dental alloys. [9],[15],[16],[17]

The findings of the present study indicate that increasing urea concentrations in a solution affect the electrochemical behavior of the tested nonprecious alloys. In particular, increased levels of urea in synthetic saliva cause a shift of the breakdown potential (E B ) in the positive direction. These data suggest that increasing urea levels can decrease both the initiation and the propagation of localized (pitting) corrosion. While the experimental results presented here showed that no hysteresis loop occurred for AuPt and that for CrNi was very small, the hysteresis loops observed for CrCo were much greater, suggestive of pitting susceptibility within the environment with higher urea concentrations. Thus the present findings indicating that AuPt and CrNi alloys should exhibit good resistance to pitting are at variance with other work which showed that CrNiMo alloys are susceptible to crevice attack and to pitting as well as retardation of repassivation under almost all experimental conditions. [8] Further, the polarization hysteresis loops suggest that CrCo alloy appears to be susceptible to pitting corrosion at all urea concentrations, a finding that appears to be at variance to a previous study. [9] The latter study reported, on the basis of cyclic polarization tests, that the corrosion resistance of CrCo alloy was improved in synthetic saliva solutions containing different salivary organics. It would appear, therefore, that urea in fact may reduce the resistance of CrCo alloys to pitting attack whereas other salivary proteins have a protective effect.

A surprising finding was that while there was an anodic shift in E corr for all alloys with increasing urea levels in solution, I corr appeared to increase, particularly for CrCo and CrNi in the 120 and 200 mg/L solutions although net decreases were found for CrNi and AuPt in the 700 mg/L solution. Further, the high I corr values for AuPt in all media were unexpected, particularly since SEM studies indicated little if any attack on the metal surface. [26],[27],[28] These results suggest that the observed I corr values may in fact not reflect metal corrosion but rather electrochemical activity of the urea at the metal surface which results in high current flow but not necessarily metal dissolution.

The findings clearly demonstrate that both the presence and the concentration of urea affected the corrosion behavior of dental alloys. This study indicates that corrosion studies that are performed in synthetic saliva solutions that do not contain salivary proteins may yield misleading results and, particularly, higher corrosion rates than may actually be found in the clinical situation. In particular, since organic components in saliva (notably proteins) can build a pellicle layer which can serve as diffusion barrier for ionic components, [29] it is possible that a reduced susceptibility to pitting attack may occur over time due to these proteinaceous salivary components. The development of organic layers on the metal surface has been reported to yield unexpectedly low corrosion potentials and to slow the cathodic oxygen reduction reaction, presumably through cathodic polarization. [30],[31] Overall, the present study and the findings of other studies indicate that caution should be exercised in recommending nonprecious alloys for prosthetic restorations. However, the present findings suggest that for patients with systemic diseases that result in increased salivary urea levels or patients with reduced salivary flow rates that result in increased levels of salivary urea, the CrNi alloy could have satisfactory corrosion resistance. In particular, the relatively corrosion resistant behavior of CrNi alloy in synthetic saliva with higher urea concentrations indicates that it would be a reasonable alternative to CrCo alloys for a patient with higher salivary urea levels that cannot afford precious metal alloys. Since results are contradictory to those obtained for tests with salivary proteins, [9] further studies testing the effect of urea and proteins on corrosion resistant behavior of CrNi alloy are needed to draw precise conclusions. Nevertheless, caution over the use of nickel-based alloys should be exercised for patients with a history of nickel allergy.

 
   References Top

1.Gil FJ, Sánchez LA, Espías A, Planell JA. In vitro corrosion behaviour and metallic ion release of different prosthodontic alloys. Int Dent J 1999;49:361-7.  Back to cited text no. 1
    
2.Jenkins GN. The physiology and biochemistry of the mouth. J. B. Lippincott Comp of Canada Ltd. 4 th ed. Toronto: Blackwell Scientific Publications; 1985. P . 284-359.  Back to cited text no. 2
    
3.Bergman M, Bergman B, Söremark R. Tissue accumulation of nickel released due to electrochemical corrosion of non-precious dental casting alloys. J Oral Rehabil 1980;7:325-30.  Back to cited text no. 3
    
4.Finne K, Göransson K, Winckler L. Oral lichen planus and contact allergy to mercury. Int J Oral Surg 1982;11:236-9.  Back to cited text no. 4
    
5.Klötzer WT, Reuling N. Biokompatibilitaet zahnaerztlicher Materialien: Teil II. Materialien mit Schleimhautkontakt. Dtsch Zahnarztl Z 1990;45:437-42.  Back to cited text no. 5
    
6.Magnusson B, Bergman M, Bergman B, Söremark R. Nickel allergy and nickel-containing dental alloys. Scand J Dent Res 1982;90:163-7.  Back to cited text no. 6
    
7.Pourbaix M. Electrochemical corrosion of metallic biomaterials. Biomaterials 1984;5:122-35.  Back to cited text no. 7
    
8.Benatti OF, Miranda WG Jr, Muench A. In vitro and in vivo corrosion evaluation of nickel-chromium- and copper-aluminum-based alloys. J Prosthet Dent 2000;84:360-3.  Back to cited text no. 8
    
9.Bilhan H, Bilgin T, Cakir AF, Yuksel B, Von Fraunhofer JA. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva. J Biomater Appl 2007;22:197-221.  Back to cited text no. 9
    
10.Brune D. Metal release from dental biomaterials. Biomaterials 1986;7:163-75.  Back to cited text no. 10
    
11.Canay S, Hersek N, Culha A, Bilgiç S. Evaluation of titanium in oral conditions and its electrochemical corrosion behaviour. J Oral Rehabil 1998;25:759-64.  Back to cited text no. 11
    
12.Kedici SP, Aksüt AA, Kílíçarslan MA, Bayramoðlu G, Gökdemir K. Corrosion behaviour of dental metals and alloys in different media. J Oral Rehabil 1998;25:800-8.  Back to cited text no. 12
    
13.Milleding P, Gerdes S, Holmberg K, Karlsson S. Surface energy of non-corroded and corroded dental ceramic materials before and after contact with salivary proteins. Eur J Oral Sci 1999;107:384-92.  Back to cited text no. 13
    
14.Metwally WA, Habib AN, Katamish HA. Corrosion and metallurgical study of some porcelain fused to metal alloys. Egypt Dent J 1995;41:1159-66.  Back to cited text no. 14
    
15.Clark GC, Williams DF. The effects of proteins on metallic corrosion. J Biomed Mater Res 1982;16:125-34.  Back to cited text no. 15
    
16.Finkelstein GF, Greener EH. Role of mucin and albumin in saline polarization of dental amalgam. J Oral Rehabil 1978;5:95-100.  Back to cited text no. 16
    
17.Holland RI. Effect of pellicle on galvanic corrosion of amalgam. Scand J Dent Res 1984;92:93-6.  Back to cited text no. 17
    
18.Ben-Aryeh H, Serouya R, Kanter Y, Szargel R, Laufer D. Autonomic neuropathy and salivary composition in diabetic patients. J Diabetes Complications 1996;10:226-7.  Back to cited text no. 18
    
19.López ME, Colloca ME, Páez RG, Schallmach JN, Koss MA, Chervonagura A. Salivary characteristics of diabetic children. Braz Dent J 2003;14:26-31.  Back to cited text no. 19
    
20.Pajukoski H, Meurman JH, Snellman-Gröhn S, Keinänen S, Sulkava R. Salivary flow and composition in elderly patients referred to an acute care geriatric ward. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1997;84:265-71.  Back to cited text no. 20
    
21.Al-Nowaiser A, Roberts GJ, Trompeter RS, Wilson M, Lucas VS. Oral health in children with chronic renal failure. Pediatr Nephrol 2003;18:39-45.  Back to cited text no. 21
    
22.Epstein SR, Mandel I, Scopp IW. Salivary composition and calculus formation in patients undergoing hemodialysis. J Periodontol 1980;51:336-8.  Back to cited text no. 22
    
23.Johansson AK. On dental erosion and associated factors. Swed Dent J Suppl 2002;156:1-77.  Back to cited text no. 23
    
24.Lugliè PF, Campus G, Deiola C, Mela MG, Gallisai D. Oral condition, chemistry of saliva, and salivary levels of Streptococcus mutans in thalassemic patients. Clin Oral Investig 2002;6:223-6.  Back to cited text no. 24
    
25.Shannon IL. Fluoride treatment programs for high-caries-risk patients. Clin Prev Dent 1982;4:11-20.  Back to cited text no. 25
    
26.Geurtsen W. Biocompatibility of dental casting alloys. Crit Rev Oral Biol Med 2002;13:71-84.  Back to cited text no. 26
    
27.Ayad MF, Ayad GM. Corrosion behavior of as-received and previously cast type III gold alloy. J Prosthodont 2010;19:194-9.  Back to cited text no. 27
    
28.Tuna SH, Pekmez NO, Keyf F, Canli F. The electrochemical properties of four dental casting suprastructure alloys coupled with titanium implants. J Appl Oral Sci 2009;17:467-75.  Back to cited text no. 28
    
29.Palaghias G. The role of phosphate and carbonic acid-bicarbonate buffers in the corrosion processes of the oral cavity. Dent Mater 1985;1:139-44.  Back to cited text no. 29
    
30.Holland RI. Use of potentiodynamic polarization technique for corrosion testing of dental alloys. Scand J Dent Res 1991;99:75-85.  Back to cited text no. 30
    
31.Khan MA, Williams RL, Williams DF. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions. Biomaterials 1999;20:631-7.  Back to cited text no. 31
    

Top
Correspondence Address:
Onur Geckili
Department of Prosthodontics, Istanbul University, Faculty of Dentistry, 2nd Floor, Capa - 34390, Istanbul
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.99043

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2]

This article has been cited by
1 Influence of the Commercial Mouthwashes on the Corrosion Behaviour of Dental Alloy
Denise Pupim, Raniel Fernandes Peixoto, Ana Paula Macedo, Regina Guenka Palma-Dibb, Maria da Gloria Chiarello de Mattos, Rodrigo Galo
Materials Research. 2022; 25
[Pubmed] | [DOI]
2 Minimization of Adverse Effects Associated with Dental Alloys
Marianna Arakelyan, Gianrico Spagnuolo, Flavia Iaculli, Natalya Dikopova, Artem Antoshin, Peter Timashev, Anna Turkina
Materials. 2022; 15(21): 7476
[Pubmed] | [DOI]
3 Comparison of Electrochemical Methods for the Evaluation of Cast AZ91 Magnesium Alloy
Jakub Tkacz,Jozef Minda,Stanislava Fintová,Jaromír Wasserbauer
Materials. 2016; 9(11): 925
[Pubmed] | [DOI]
4 Comparison of Electrochemical Methods for the Evaluation of Cast AZ91 Magnesium Alloy
Jakub Tkacz,Jozef Minda,Stanislava Fintová,Jaromír Wasserbauer
Materials. 2016; 9(11): 925
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
    Materials and Me...
   Results
   Discussion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed10987    
    Printed464    
    Emailed1    
    PDF Downloaded93    
    Comments [Add]    
    Cited by others 4    

Recommend this journal