Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
HOME | ABOUT US | EDITORIAL BOARD | AHEAD OF PRINT | CURRENT ISSUE | ARCHIVES | INSTRUCTIONS | SUBSCRIBE | ADVERTISE | CONTACT
Indian Journal of Dental Research   Login   |  Users online:

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         

 


 
ORIGINAL RESEARCH Table of Contents   
Year : 2012  |  Volume : 23  |  Issue : 4  |  Page : 473-478
Evaluation of reliability and reproducibility of linear measurements of cone-beam-computed tomography


1 Ribeirão Preto Dentistry College (FORP/USP), Oral and Maxillofacial Surgery Post-Graduation Student. Ribeirão Preto, SP, Brazil
2 Pernambuco Dentistry College (FOP/UPE), Camaragibe, PE, Brazil
3 Sergipe Federal University (UFS), Aracaju, SE, Brazil

Correspondence Address:
Thiago de Santana Santos
Ribeirão Preto Dentistry College (FORP/USP), Oral and Maxillofacial Surgery Post-Graduation Student. Ribeirão Preto, SP
Brazil
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.104952

Rights and Permissions

Objective: it was to evaluate intra- and interexaminer reliability and reproducibility of linear measurements in cone-beam tomography (CBCT) images. Materials and Methods: CBCT scans were obtained from 50 patients of a private clinic. Two examiners located the landmarks twice in two-dimensional and three-dimensional images on different days, with images performed 1 week apart. Intra- and interexaminer reproducibility and reliability were analyzed. Results: the measurement error (ME) did not show significant differences between intra- and interexaminers. The intraclass correlations (ICC) between the intra- and interexaminer readings obtained with the different methods showed almost perfect matches. The results demonstrated high examiner reproducibility for linear and volumetric parameters with high intraclass correlation coefficient (ICC) and coefficient of variation (CV). The ICC showed that the methodology was highly reliable and reproducible (ICC- >0.99 and CV <1.5%). Conclusion: the measurements demonstrated strong agreement between examiners and significant reliability and reproducibility. Therefore, this methodology can serve as a standard for linear measurement analysis of the topography of mandibular canal and osseous adjacent structures.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed7959    
    Printed397    
    Emailed2    
    PDF Downloaded181    
    Comments [Add]    
    Cited by others 8    