Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
HOME | ABOUT US | EDITORIAL BOARD | AHEAD OF PRINT | CURRENT ISSUE | ARCHIVES | INSTRUCTIONS | SUBSCRIBE | ADVERTISE | CONTACT
Indian Journal of Dental Research   Login   |  Users online:

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         

 


 
ORIGINAL RESEARCH Table of Contents   
Year : 2014  |  Volume : 25  |  Issue : 6  |  Page : 686-691
Evaluation of linear dimensional accuracy of hard chairside and laboratory heat cure reline resins at different time intervals after processing


1 Department of Prosthodontics, School of Dental Sciences, Krishna Institute of Medical Sciences, Deemed University, Malkapur, Karad, Satara, Maharashtra, India
2 Department of Prosthodontics, Tatyasaheb Kore Dental College and Research Center, New Pargaon, Hatkanangale, Kolhapur, Maharashtra, India

Correspondence Address:
Shivsagar Tewary
Department of Prosthodontics, School of Dental Sciences, Krishna Institute of Medical Sciences, Deemed University, Malkapur, Karad, Satara, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.152162

Rights and Permissions

Context: Relining with heat cure denture base resin is time-consuming and the patient has to remain without dentures within this period. Recently, some autopolymerizing resins marketed as hard chairside reline systems with low exothermic heat allow the dentists to reline prosthesis directly in the mouth. However, the decision to use these materials must be based on physical properties such as dimensional accuracy that directly influences the accuracy of fit of the denture base. Aim: The aim was to compare the linear dimensional changes of two hard chairside reline resins with two laboratory heat cure resins at 3 times intervals after processing. Settings and Design: A stainless steel split mold (International Organization for Standardization 1567) was used for sample fabrication. Five measurements of the reference dimensions (AB and CD) were measured directly from the mold and the samples with a profile projector, and mean difference were calculated. Subjects and Methods: Forty samples were fabricated by incorporating the split mold into first pour of denture flasks and packing each of the chairside reline resins ("Kooliner" and "Ufi Gel Hard") and laboratory heat cure resins ("Dental Products of India Heat Cure" and "Trevalon"). The mean difference in dimensional change at 3 times intervals (0 h, 4 days and 2 months) were calculated and subjected to statistical analysis. Statistical Analysis Used: One-way ANOVA, RMANOVA and post hoc Tukey's tests. Results: All resins showed different levels of significant shrinkage (P < 0.001) after processing (T 0 ) ranging from −0.128 to −0.310 mm. After 4 days (T 1 ), there was significant shrinkage (P < 0.001) ranging from −0.168 to −0.296 mm. After 2 months (T 2 ), there was again significant shrinkage (P < 0.001) ranging from −0.018 to −0.216 mm. Chairside reline resins showed less dimensional shrinkage at each time interval than the laboratory heat cure resins. Conclusions: Hard chairside resins are dimensionally accurate than the laboratory heat cure resins.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed5999    
    Printed411    
    Emailed1    
    PDF Downloaded167    
    Comments [Add]    

Recommend this journal