Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
HOME | ABOUT US | EDITORIAL BOARD | AHEAD OF PRINT | CURRENT ISSUE | ARCHIVES | INSTRUCTIONS | SUBSCRIBE | ADVERTISE | CONTACT
Indian Journal of Dental Research   Login   |  Users online:

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         

 


 
ORIGINAL RESEARCH Table of Contents   
Year : 2015  |  Volume : 26  |  Issue : 6  |  Page : 598-602
Adverse events associated with ultrasonic scalers: A manufacturer and user facility device experience database analysis


Department of Dentistry, Madurai Medical College and Hospital, Madurai, Tamil Nadu, India

Correspondence Address:
Dr. Rajagopal Athmarao Thennukonda
Department of Dentistry, Madurai Medical College and Hospital, Madurai, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.176923

Rights and Permissions

Background: The present study was conducted to determine the frequency and type of adverse events (AEs) associated with ultrasonic scaler reported to the Food and Drug Administration manufacturer and user facility device experience (MAUDE) database. Materials and Methods: The authors reviewed the ultrasonic scaler units (USU) related AEs reported to MAUDE from October 1, 1995, to September 31, 2015. Analyses of details collected are presented. Results: MAUDE received a total of 667 unique USU-related AE reports. Of 667 cases, MAUDE classified 628 instances (94.2%) as malfunction 27 (4%) as injurious, 10 (1.5%) as others, and 2 (0.3%) claiming the use of USU as cause of death. Of the 667 cases, 511 (76.6%) were used for endodontic application, and 147 (22%) as scaler applications. In 512 (76.8%) instances, there was separation of the tips, posing danger to patients or users, and 112 (16.8%) instances of overheating, 12 (1.8%) instances of breakage, and electrical issues in 8 (1.2%) instances. These AE resulted in 19 instances of thermal injury, 2 suspicious deaths, and hearing loss in 3 cases. In 4 cases, patient swallowed broken parts requiring additional medical care. Conclusions: Use of USU, a Class 2 device without exemption, carries a degree of risk to patient's safety, if not properly used. As of today, MAUDE data is the only reliable source of AE until another database or such study is carried out. Certain AE that has been largely anecdotal, such as hearing loss has been reported in this study. The findings from study reiterate that more in-depth analysis of AE of USU is needed. Until then operator needs to take all precautions to avoid AE when using USU.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed10616    
    Printed351    
    Emailed0    
    PDF Downloaded135    
    Comments [Add]    
    Cited by others 2    